Swedish Team Tests an Ozone Blood Circuit Against Sepsis in an Early Lab Study
In a small animal study from Uppsala University, pigs given an hour of ozone treatment in a blood circuit kept normal blood pressure during sepsis.
Treating blood with ozone outside the body, then returning it, is the idea behind EBO2 (also called EBOO). A research team led from Uppsala University in Sweden is testing the same principle in a very different setting: intensive care for sepsis, the body’s runaway reaction to a serious infection.
Their latest results were published on October 25, 2026 in the journal Critical Care: Sepsis and Severe Infection. The study is small and was done in animals, so it says nothing yet about treating people. It is still worth knowing about, because it measures what an ozone blood circuit does in a living body with the tools of an intensive care unit.
How the study worked
The researchers describe sepsis as the third leading cause of death worldwide and note that, apart from steroids, no treatment aimed at its out-of-control inflammation has been shown to clearly improve outcomes. Their earlier experiments suggested that ozone in a blood circuit can kill gram-negative bacteria, the type used in this study, and lower a key inflammation signal, so this time they looked at the outcomes doctors watch in an intensive care unit.
Nine anesthetized pigs were given an infusion of bacteria to bring on sepsis. Four were then connected for one hour to a circuit that drew blood out, passed it through a chamber of oxygen with a small share of ozone, and returned it. Five had standard intensive care only. All nine were followed for two more hours.
Organ function was graded with the SOFA score, the same scale hospitals use to rate how badly a patient’s organs are failing.
What the researchers saw
The treated animals did better on the measures tied to circulation:
- Organ failure scores were lower in the treated group at the end of the study, mainly because their circulation held up.
- Blood pressure stayed normal without blood pressure drugs in the treated animals. Four of the five untreated animals needed a blood pressure drug.
- Lactate, a sign of shock, reached the warning level in one treated animal and in four of the five untreated ones.
- Bilirubin, a liver marker, was about twice as high in the untreated group.
Not everything moved. Two inflammation signals were lower in the treated group, but the gap was not statistically significant in a study this small. Breathing scores did not differ significantly either. The team also checked whether the circuit was damaging red blood cells in two of the treated animals and found no change they considered clinically relevant.
What it does not show
The authors list the limits themselves. There was no group that went through the whole procedure without ozone, so the catheter, the blood thinner or the oxygen could explain part of the effect. Nine animals is a very small number, the follow-up lasted hours, and they say safety still needs full testing before the approach could be tried in patients. The company that makes the circuit paid for most of the research costs.
They describe the results as promising and as a reason to run larger, longer studies.
What it means if you are looking at EBO2
This was a research device used on anesthetized animals in a laboratory model of intensive care. The study did not involve the equipment or the setting of a clinic EBO2 session, and it is not evidence that an EBO2 session treats an infection. Anyone with signs of a serious infection needs emergency medical care.
What the study does add is careful measurement. Blood pressure, organ function, inflammation signals and red blood cells were all checked as blood met ozone in a circuit, and the first numbers point in a good direction. For where the human evidence stands today, read does EBO2 work? and browse the studies in our research library. To see how a clinic session works, start with what is EBO2.